Interview Questions
If
ESXi host is down, what u will do
Esx
Host Not Responding Error
1…Ping
the ip of the esxi host. It will ping…
2…Login
using putty & use this command
#
service mgmt-vmware restart (Restart
the mgmt-vmware service )
3…If
still problem …then kill the process
#
ps -ef | grep hostd
This
will output a list of processes .
root
23955 1 0 10:42 pts/1 00:00:00 /bin/sh /usr/bin/vmware-watchdog
-s
hostd
–u
60 -q 5 -c /usr/sbin/vmware-hostd-support /usr/sbin/vmware-hostd -u
root 23961
23955 4 10:42 ? 00:00:15 /usr/lib/vmware/hostd/vmware-hostd
The
first process is using the vmware-watchdog,
The
second line is using hostd
. kill the process.
virtual
machines will run so don’t worry about that.
#
kill -9 23961
Now
the hostd service will start and after a few seconds
Host
and virtual machines will be up in vCenter.
4…If
you can’t kill or restart services.. Then reboot the ESXi host...
If
ESXi hosts Disconnected Error.
1…
Right
click the esxi host
Reconnect.
2….If
not connecting… ping the ip add of host & vCenter.
3.…
Open Putty … enter these
commands
service
mgmt-vmware
restart (restarts host agent (hostd)
on vmware
esx server)
service
vmware-vpxa
restart
(restarts Vcenter
agent service)
service
network restart
(restarts management networks on ESX)
4…Remove
the ESX/ESXi host from the vCenter Inventory.
Add
the ESX/ESXi host back to vCenter Inventory.
Restart
the ESXi Management Agents resolves the issue.
3…If
VCenter is down, what will happen, How will you Troubleshoot
1…If
vCenter is down, hosts and virtual machines are not affected
2…HA,
FT will work
3…DRS
do not work
How
HA works
HA
will work, because HA agent running on each host and the hosts
monitor each other
and
keep lists of running VMs that has to be restarted in case of a host
failure. VCenter is
Just
used to configure HA and De-activate.
Why
DRS Do not work
DRS
will NOT work without vCenter, because vMotion recommendations are
computed
by
the vCenter service, and it also initiates the migration processes
How
will you Troubleshoot
#
Go to services Restart
VMware Virtual Center Server service
#
If not starting Restart the SQL Server service
Restart Virtual Center Server service
#
verifies SQL server database connectivity. (Check ODBC Connection
test)
#
verifies SQL server space, clear old unwanted logs and creates space.
#
Defragment Database if the database is heavily fragmented vCenter
Server may not start.
#
Verify the VMware Virtual Center Service is running
with proper login & pwd.
#
Verify that critical folders exist on the vCenter Server host.
Note:
In Windows 2008 (64-bit), these folders are located at:
C:\ProgramData\VMware\VMware
VirtualCenter\sysprep
C:\ProgramData\VMware\VMware
VirtualCenter\docRoot\diagnostics
#
Verify that no hardware or software changes made to the vCenter
server that created the
problem.
If any changes made recently uninstall those H/W or S/W
#
Stop IIS
service in
the vCenter server, and then restart vCenter service.
#
VCenter logs are vpxd logs will help.
Windows
2008 located at C:\ProgramData\VMware\VMware VirtualCenter\Logs
4…
Unable to Power on a VM, what will u do?
#
Problem with storage
#
Not enough RAM
or CPU
to power on the vm
#
Problem with corrupted vmx file, VM files not accessible.
#
Swap
file locked
by another process
5…Unable
to Power off a VM...What u will do
#
Check the running processes and Kill
First
find the Id. to get a list of running vms, to find World ID, UUID,
and Display Name
the
command is
esxcli
vm process list
esxcli
vm process kill –t soft -w WorldID
esxcli
vm process kill –type=[soft,hard,force] –world-id=WorldNumber
soft
– Normal shut down .
hard
– it will shut down the OS before properly closing applications.
force
- it will force the VM to switch off just like pushing a power switch
6…
Snapshot or Clone, which is better to keep for one month? Why?
Clone
should be used. B’cos it will give good performance if we are going
to use for long
time.
Snapshot
should not be used for more than 3 or 4 days. It will affect the
performance.
7…IF
u deletes a snapshot what will happen
When
you delete all snapshots for a VM, all of the delta files are merged
back into the
original
VMDK file.
If
you delete an individual snapshot, that snapshot is merged into its
parent snapshot.
if
Snapshot Deletion fails
or delta disk is not committed back to its parent disk
We
have to use Snapshot
Consolidation
method.
To
consolidate the snapshot files
Right-click
the virtual machine
Snapshot
Consolidate.
Check
the Need
Consolidation
column to check the task succeeded or not.
Right-click
the menu bar of that vm column
Needs
Consolidation
A
Yes
status
means vms should be consolidated.
A
No
status
indicates that the files are OK.
8…
If
u creates a snapshot what will happen.
When
you create a snapshot, the flat-vm.vmdk file becomes read-only.
And
create a new “delta.vmdk” file in its name.
It
starts writing into this delta file, and will not touch the original
.vmdk file
(which
represents a virtual machine’s hard drive)
Initial
Snapshot File size is 16MB
Snapshot
files: vm-number.vmdk
, vm-number-delta.vmdk, vm.vmsd
9…How
to keep 2 vms in a particular host.
Create
Affinity Rules using DRS Groups Manager
(Check
my “all others “Document)
10…
Patching process,
if there is a problem after patching what you will do.
Use
Update Manager for Patching
Command
for Patching
esxcli
software vid install -d: This command will install a specified file
esxcli
software vid install -d /vmfs/volumes/datastore/patches/file.zip.
esxcli
software vid list:
list of all patches & updates installed on the ESX/ESXi host
If
there is a problem after patching what will you do.
Steps
to Rollback if there is a problem
Reboot
the Esxi server
press SHIFT+R to access recovery mode
Connect
to the host using ILO, DRAC, RSA, etc.
Reboot
the ESXi hosts
Press
SHIFT+R to enter into recovery mode
It
will prompt with a new screen with the Hypervisors installed. One
would be the
default which is
Update1
To
confirm Roll back Press Y
Server
will be rebooted and reverted to the previous version of ESXi 5
Command
to remove
the Patch
esxcli
--server=server_name software vib remove --vibname=name
11…
Command to check lun details, HBA card, Serial number,
esxcli
storage core path list
Lists all LUN paths currently connected to the ESXi host.
esxcli
storage core device list
gives a list of LUNs currently connected to the ESXi host.
12…Command
to check vms process list & kill the process.
esxcli
vm process list
esxcli
vm process kill –t soft -w WorldID
|
13…
How will you Enable SSH
Command
to Enable : vim-cmd hostsvc/enable_ssh
Command
to start : vim-cmd hostsvc/start_ssh
To
Enable in GUI
:
Click
the Host
Configuration
Security Profile
Properties
14…What
are the Esxi Sever Partitions
Bootpartition
(4 MB): This
partition is needed for booting
Bootbank
(250 MB):
Boot Image is saved on this FAT partition.
It will be
extracted during the boot process and loaded into the system memory.
vSphere
4 this file size is 70 MB, vSphere 5 file size 250 MB.
AltBootbank
(250
MB): This
partition is empty after a fresh install. Once we update of
ESXi,
the current image is copied from the bootbank partition to here.
This makes it possible to return to the last known good
configuration by typing “Shift + R”
while
booting if there occurs an error during the update of an ESXi host.
Dump/crash
partition (110 MB): In
the case of a total crash of the host a dump file is
written
on this partition.
Store
(285 MB):
Different ISO files for the VMWare Tools are available for all
supported
operating systems.
Scratch
partition
(4 GB): This
partition is only created if the installation media has at
least
5 GB of space. It is used for the log files of the VMKernel.
If this partition is missing, the logs of the host are lost after
a reboot or shutdown.
15…What
is host isolation. How Host Isolation is detected?
ESX hosts uses heartbeats to communicate with
other hosts in the cluster.By
default,
Heartbeat
will be sent every 1 second.
If a
ESX host didn't
receive
heartbeat for 13 seconds from any other hosts, The host will
consider
it as isolated and host will ping the configured isolation
address(default
gateway
by
default). If the ping fails, VMware HA will execute the Host
isolation response
16…HA
– AAM, FDM
Esxi
4.1
- AAM
- Automated Availability Manager
Esxi
5.0 - FDM
- Fault Domain Manager
AAM
is the agent of HA in Esxi 4.1
FDM
is the name of the agent in Esxi 5.0
The
primary/secondary node mechanism in Esxi 4.1
Master
Host , Slave Host concept in Esxi 5.0
The
FDM Agent
is responsible for communicating host resource information, Hosts
&
vm status and HA properties to other hosts in the cluster heartbeat
mechanisms,
vm
placement, vm restarts,
log
file is stored
/var/log/ fdm.log
FDM
Master
----
The FDM Master monitors all hosts and VMs and slave hosts.
----
if host failure happens, the master restarts all VMs on another host.
----
It keeps a list of VMs protected, which is updated after every power
off or on done by user.
----
keeps track of any adding/removing of hosts.
----
sends periodically status reports to vCenter
Slave
---
A slave monitors the vms it is running and informs the master about
any changes.
---
The slave also monitors the health of the master by monitoring
heartbeats.
---
If the master fails, the slaves initiate and participate in the
election process.
Datastore
Heartbeat - New concept in 5.0
---
If the primary network goes down this secondary network is used to
find out
Whether
the host is failed or isolated / partitioned host.
--- It Prevents
Unnecessary Restarts due to isolation
17…What
is the Pre-Requesties of HA, Vmotion
VMotion
Pre-requisites
-
Compatible Processors - Source and Destination hosts should have
compatible
processors
-
VMotion requires a Gigabit Ethernet network between hosts
-
Shared Storage
-
All virtual machines files should be accessible by source and
target hosts
-
Virtual machine swap files should be accessible to source and
destination hosts
-
Create vmkernal port and VMotion-enabled managed hosts.
-
Port Number 8000 should be opened.
-
Configure all managed hosts to use shared VMFS volumes
-
Ensure the VMFS volume has space to store all virtual disks of
virtual Machines
-
Ensure all VMFS volumes on source and destination hosts use volume
names, and all
virtual
machines use those volume names for specifying the virtual disks.
HA
prerequisites:
-
Compatible Processors
-
requires a Gigabit Ethernet network between hosts
-
Shared Storage
-
All hosts must be licensed for VMware HA.
-
All virtual machines files should be accessible by source and
target hosts
-
Each ESX server in the cluster should have access to the virtual
machines’ files and should be
able
to power on the virtual machine without a problem
-
You need at least two hosts in the cluster.
-
All hosts need a unique host name.
-
All hosts need to be configured with static IP addresses. If you are
using DHCP, you
must
ensure that the address for each host persists across reboots.
-
All hosts must have access to the same management networks
18…How
will you Trouble Shoot Vmotion Failure
If
VMotion fails:
1.
Check whether CPU is compatible
2.
Check the ports 8000 is open or not
3.
Enough resources must be
made available on the target ESX/ESXi host
4.
Verify
that the required disk space is available.
5.
Ensure VMKerenl Port configured , VMotion Option is enabled
6.
Vmkping x.x.x.x
Enter
the hostname or IP address of the server that you want to ping
7.
Verify that time is synchronized across environment
8.
if reconnecting the ESXi host resolves the issue
9.
Ensure CD-ROM is not mounted.
10. Storage - unresponsive/busy
disk, network timeouts...
Which
Logs to check for vmotion failures
check
VMkernel logs
on both source and destination host for clues to failure.
VMkernel
logs - /var/log/vmkernel
check
hostd logs
on both source and destination host.
Hostd
logs - /var/log/vmware/hostd*.log
19…How
will you Trouble Shoot HA Failure
1. Check
any network problem exists
2. Check the DNS is configured
properly
3. Check HA agent status using command -
service vmware-aam status
4. Check hosts named uniquely .
5.
Check HA related ports are open in firewall to allow for the
communication
Incoming
port: TCP/UDP 8042-8045
Outgoing port:
TCP/UDP 2050-2250
6. Try to restart /stop/start the HA agent on the affected
host using the below
commands.
try to restart vpxa and management agent in the Host.
service vmware-aam restart
service vmware-aam stop
service vmware-aam start
7. Right Click the
affected host and click on "Reconfigure for VMWare HA" to
re-install
the
HA agent that particular host.
Goto
cluster settings and uncheck the vmware HA to turnoff the HA in that
cluster and
re-enable
the vmware HA to get the agent installed
8.
Remove the affected host from the cluster and add. To Remove the host
-- put into
Maintenance
mode.
20…Is
it possible to Vmotion from one cluster to another cluster
Requirements:
1)
ESX Servers must be managed by the same Virtual Center server
2)
The VMs disk files must be stored on shared storage
3)
Hosts Must have compatible CPUs
4)
ESX Servers must be in same network segment configured with VMkernel
ports enabled
for
vmotion
5)
Enable
Jumbo
Frames
for
Maximum
Latency between the sites
6) The IP subnet of the virtual machine must be accessible for
both source and destination
ESX
servers
21…
5.0. 5.1 New Features
5.0
Storage
Distributed Resource Scheduler (SDRS)
Profile-Driven
Storage
Auto-Deploy
VMware
vSphere Storage Appliance
VCenter
Server Appliance
New
virtual machine version version 8
5.1
ESXi/vSphere
5.1 License is per-CPU-socket based . Not vRAM based like 5.0
Support
more recent hardware (both Intel and AMD). New "Version 9
virtual hardware"
It
is possible to allow any VM generated on VMware ESX Server 3.5 or
later to continue to
run
on ESXi 5.1 unchanged (i.e., without being forced to shut down,
update to the version 9
virtual
hardware, and restart)
ESXi
5.1 comes with hardware accelerated 3D Graphics support.
vSphere
Replication is now available independently from
SRM.
vSphere Replication allows
to
mirror a VM to another datastore, it can be restarted there when the
primary storage fails.
So
far you could use vSphere Replication only together with the Site
Recovery manager
(SRM)
product,
Zero
downtime VMware Tools Upgrade.
Once the new VMware tools of vSphere 5.1
installed
in a VM then you can later upgrade that to any newer version without
rebooting a
VM.
Enhanced
VMotion
Enhanced
VMotion allows to migrate a VM from one host to another and
to
a different
storage
at the same time without the need to power off the VM!
This
enables you to live migrate a VM between different clusters (that
usually do not share
any
storage) or even between different stand alone hosts that each use
local storage only.
22…Port
Groups
vSwitches
can be divided into smaller units called port groups
Port
Groups are nothing but the VLANs or virtual local area networks
1.
Virtual Machine Port Group - Used for Virtual Machine Network
2. Service Console Port Group - Used for Service Console
Communications
3. VMKernel Port Group - Used
for VMotion, iSCSI, NFS Communications
5.0
1.
Virtual Machine Port Group - Used for Virtual Machine Network
2. VMKernel Port Group - Used for VMotion, iSCSI, NFS
Communications
The
management vmkernel port on ESXi 5.0 is same as Service Console port
on ESX
23…Port
Numbers
443
– Communication between vCenter Server to vSphere Client
902
-- VCenter Server to hosts. hosts send heartbeat over UDP port
902 to the vCenter
Server
HA Ports
Incoming port: TCP/UDP 8042-8045
Outgoing port: TCP/UDP 2050-2250
Vmotion
Port – 8000
P2V
Ports
443 and 902 - Source to
ESX/VC
445 and 139 - Converter to
source and source to Workstation/Server
9443
– web client
24…What
are the files in a Virtual Machine ?
.vmx - Virtual Machine Configuration File
.nvram - Virtual Machine BIOS
.vmdk - Virtual Machine Disk file
.vswp - Virtual Machine Swap File
.vmsd - Virtual MAchine Snapshot Database
.vmsn - Virtual Machine Snapshot file
.vmss - Virtual Machine Suspended State file
.vmware.log - Current Log File
.vmware-#.log - Old Log file
25….Difference
between Standard vswitch , Distributed vSwitch
--
One Standard VSwitch
per host. Cannot connect multiple hosts.
A
Distributed Switch can connect multiple hosts.
--
Standard VSwitch
Managed at host level.
A
Distributed Switch managed at Cluster Level.
--
STP
Spanning-Tree
Protocol
is
not in vswitches. Its only in Distributed switch.
It
prevents loops in the LAN and selects the fastest network Links.
If
one network link goes down, Spanning Tree will use the alternate
link.
--
A vSwitch does not perform IGMP
Snooping.
. Its only in Distributed switch
IGMP
Snooping
allows switches to read IGMP packets and forwarding network
packets
based on their content.
--
DvSwitches also support distributed port groups or dvport groups.
26…Maximum
Minimums
ESX
5.1 ESX 5 ESX 4.1
VCPUs
per vm 64 32 8
CPUs
per host 2048 2048 512
RAM
per vm 1TB 1TB 255GB
RAM
per host 2TB 2TB 1TB
Check
for other details………I cant copy paste all…..
27…Esx
Esxi Difference
ESXi
Server has no service
console
ESXi
Server uses RCLI (Remote command line interface) instead of service
console
utilities
ESXi Server is extremely thin = fast
installation + faster boot
ESXi is so small that it can be easily installed and can even be
booted from a
USB
Flash disk
ESXi
Server’s service console (firewall) is configured differently
ESXi Server has a “yellow
firmware console”
ESXi Server has server health status built in
ESXi Server requires fewer
patches and less rebooting
ESX
server can be connected
through direct-attached serial cable.
ESXi
does not support interaction through direct-attached serial cable.
ESX
supports Active Directory integration through third-party agents
installed on the
Service
Console.
ESXi
allows users to login directly and authenticate in AD using a local
username and
password.
28…Tell
P2V steps
Take
Backup of Physical Server
Note
Down HostName , Ip Add, GW, DNS Ips.
C:
D: Info…. Take a Screen Shot of it.
Stop
the following services:
Start
– Run – services.msc and click on Status until the Started
services are listed first.
Backup
services. Examples:
TSM, NetBackup.
Database
services.
Examples: SQL, Oracle, MySQL, Exchange Serve.
Anti-Virus
software.
Examples: McAfee, Norton, Trend Micro.
Web
Hosting services.Examples:
World Wide Web Publishing service, IIS, Apache.
Print
Spooler service.
Disable
the following services:
All
vendor-installed hardware management services.
All
update services that are set to “Automatic” startup
Examples:
Windows Update/Automatic Updates, Altiris, PatchLink Update.
Start
the Following Services
Server
and Workstation processes ,Volume Shadow Copy and Microsoft Software
Shadow
Copy Provider are started.
Start
P2V Process
RDP
into the machine from which you will run VMware Converter Standalone
Client 5.
Steps
after Conversion
Remove
any Serial Ports or USB Adapters from the hardware list if any are
shown.
Check
RAM size and the number of CPUs is correct.
In
the “Network
Adapter”
section, “Connect at power on” check box not ticked.
Correct
VLAN selected.
Now
Power-On the Converted VM
Install
VMware Tools
Remove
all vendor-installed hardware management programs from “Add/Remove
Programs”.
Remove
the VMware Converter Agent software from “Add/Remove
Programs”.
Remove
any physical hardware drivers from “Add/Remove
Programs”
such as display drivers.
Do
not reboot if prompted.
Go
to a CMD prompt and type:
SET
DEVMGR_SHOW_NONPRESENT_DEVICES=1
and
then
DEVMGMT.MSC
to open Device Manager
and
then select “Show
Hidden Devices”
from the Device Manager “Action”
or “View”
menu.
RDP
into the source machine Disable
the NIC card
virtual
machine Edit
Settings
network cardclick
the “Connect”
then the “Connect
At Startup”
Power
on The VM
and Check the services and start the services.
29…Esxi
4.1 & Esxi 5.0 License Difference
4.1
Based on CPU Core
5.0
Based on RAM
-
Based
on CPU Core
30…Why
cant upgrade from 3.5, 4.0 to 5.0
5.0
Uses 64 bit Hardware and OS
So
upgrade to 4.1 then to 5.0
3.5,
4.0 Boot Partition is 1 GB.. 5.0 is 4 MB
Important
Commands will be asked
To
check the Hardware details : esxcli
hardware platform get
UUID:
0x74 0xd3 0x36 0x4 0x3c 0xe7 0x11 0xdf 0x0 0x0 0x0 0x0 0x0 0x0 0x0
0x11
Product
Name: N20-B6625-1
Vendor
Name: Cisco Systems Inc
Serial
Number: FCH1432V1HY
IPMI
Supported: true
Show
ESXi version and build : esxcli
system version get
To
Find hostname.
: # esxcli system hostname get
To
Poweroff, Reboot a host, it must be in maintenance mode
Power
off a host : #
esxcli system shutdown poweroff --delay=10 --reason=”Hardware
maintenance”
(
Delay and Reason parameter must be provided. )
Reboot
the host :
esxcli system shutdown reboot -d 10 –r “Patches applied”
Enter
Maintenance Mode : esxcli
system maintenanceMode set –enable yes
Exit
maintenance Mode : esxcli
system maintenanceMode set --enable no
esxcli
storage core path list
Lists all LUN paths currently connected to the ESXi host.
esxcli
storage core device list
List of LUNs currently connected to the ESXi host.
esxcli
storage filesystem list : List of all datastores mounted to an ESXi
host
esxcli
storage core adapter list -- To find HBA WWN
on ESXi 5.0
Configuration
tab
Hardware
Storage Adapters:
To
list the available port groups : esxcli
network vswitch standard portgroup list
list
current vswitch configuration : esxcli network vswitch standard list
list
NIC cards and their link state : esxcli network nic list
list
Distributed Switch configuration : esxcli network vswitch dvs vmware
list
list
vmkernel interfaces and configuration : esxcli network ip interface
list
How
will you remove a LUN from a host
ESX/ESXi
4.1
The
best practices for removing a LUN from an ESX 4.1 host
Unregister
all objects from the datastore including VMs and Templates
Ensure
that no 3rd party tools are accessing the datastore
Ensure
that no vSphere features, such as Storage I/O Control, are using the
device
Mask
the LUN from the ESX host by creating new rules in the PSA (Pluggable
Storage Architecture)
Physically
unpresent the LUN from the ESX host using the appropriate array tools
Rescan
the SAN
Clean
up the rules created earlier to mask the LUN
Unclaim
any paths left over after the LUN has been removed
Esxi
5.0
1.
Unregister all objects from the datastore including VMs and Templates
2.
Ensure that no 3rd party tools are accessing the datastore
3.
Ensure that no vSphere features, such as Storage I/O Control or
Storage DRS, are using the
device
4.
Detach the device from the ESX host; this will also initiate an
unmount operation
Choose
the Devices View (Under Configuration > Storage):
To
Patch an ESXi 5.0 host from the command line:
“ Install
“ command overwrites the existing packages. It may downgrade
the existing packages,
Overwrite
existing drivers.
“ Update”
command is the recommended. It will update from lower version to new.
Patching
Steps
-
Patches
can be downloaded from the VMware
patch portal. Select ESXi
(Embedded and Installable)
in the product dropdown and click Search.
-
Upload
the patch to a datastore using the Datastore
Browser
from vCenter or a direct connection to the ESXi 5.0 host using the
vSphere client.
-
Log
into the local Tech Support Mode console of the ESXi 5.0 host.
-
Migrate
or power off the virtual machines and put the host into maintenance
mode.
# vim-cmd hostsvc/maintenance_mode_enter
-
Navigate
to the directory on the datastore where the patch file was uploaded
# cd /vmfs/volumes/Datastore/DirectoryName
#
ls
Where Datastore
is the datastore name where the patch file was uploaded to, and
DirectoryName
is the directory you created on the datastore.
-
Install
or update a patch on the host using these esxcli commands:
-
To
Install:
Using
local setup:#
esxcli software vib install -d
"/vmfs/volumes/Datastore/DirectoryName/PatchName.zip"
-
esxcli
software vib install -d
/vmfs/volumes/[DATASTORE]/[PATCH_FILE].zip
Where
PatchName.zip is the name of the patch file you uploaded to the
datastore.
# esxcli software vib install -d
"/vmfs/volumes/datastore1/patch-directory/ESXi500-201111001.zip"
-
Using
http setup:
#
esxcli software vib install -v viburl
Where
viburl
is the URL to the http depot where VIB packages reside.
#
esxcli software vib install -v
https://hostupdate.vmware.com/software/VUM/PRODUCTION/main/esx/vmw/vib20/tools-light/VMware_locker_tools-light_5.0.0-0.7.515841.vib
To
Update:
Using
local setup:#
esxcli software vib update -d
"/vmfs/volumes/Datastore/DirectoryName/PatchName.zip"
Where
PatchName.zip
is the name of the patch file you uploaded to the datastore.
#
esxcli software vib update -d
"/vmfs/volumes/datastore1/patch-directory/ESXi500-201111001.zip"
-
Using
http setup:
# esxcli software vib update -v viburl
Where
viburl
is the URL to the http depot where VIB packages reside.
-
#
esxcli software vib update -v
https://hostupdate.vmware.com/software/VUM/PRODUCTION/main/esx/vmw/vib20/tools-light/VMware_locker_tools-light_5.0.0-0.7.515841.vib
-
Verify
that the VIBs are installed on your ESXi host:#
esxcli software vib list
Name
Version
Vendor Acceptance Level Install
Date
----------------- --------------------------- ------
----------------------------------------------------
ata-pata-amd
0.3.10-3vmw.500.0.0.469512 VMware VMwareCertified
2012-05-04
ata-pata-atiixp
0.4.6-3vmw.500.0.0.469512 VMware VMwareCertified
2012-05-
-
After
the patch has been installed, reboot the ESX host:
# reboot
-
After
the host has finished booting, exit maintenance mode and power on
the vms .
# vim-cmd hostsvc/maintenance_mode_exit
Install
vmtools
Install
VMware Tools:
1.
Download and install the keys:
Create a file
vmware-tools.repo under path /etc/yum.repos.d/with the below
content –
Install the VMware
Tools with below command
To perform a
silent, non-GUI with suppressed reboot VMware Tools installation in a
Windows guest operating system:
In ESXi 5.0.x and earlier
versions, run this command:
setup.exe
/S /v"/qn REBOOT=ReallySuppress
In ESXi
5.1.x, run this command:
setup.exe
/S /v"/qn REBOOT=R"
To
collect diagnostic information using the script on a Linux host
-
Confirm
what version of VMware Server you are running, type:vmware
-v
-
Change
to the directory where you want the vm-support output to appear. For
example:cd
/tmp
-
Run
the script:/usr/bin/vm-support
-
When
the script finishes, it informs you of the output .TGZ
filename and location
esxcfg-dumppart
http://kb.vmware.com/selfservice/microsites/search.do?language=en_US&cmd=displayKC&externalId=1006796
[root@az84vm4
/]# esxcfg-dumppart
esxcfg-dumppart
<options> [<partition>]
-l|--list
List the partitions available for Dump Partitions.
WARNING:
This will scan all LUNs on the system.
-t|--get-active
Get the active Dump Partition for this system,
returns
the device identifier for the partition
(naa.xxxxx:1)
or 'none'.
-c|--get-config
Get the configured Dump Partition for this
system,
returns the device identifier for the partition
(naa.xxxxx:1)
or 'none'.
-s|--set
Set the Dump Partition for this system and activate it,
either
naa.xxxxx:1 or 'none' to deactivate
the
active dump partition.
-f|--find
Find usable Dump partitions and list in order of
preference.
-C|--copy
Copy a dump file from the dump partition:
-D
--devname /vmfs/devices/disks/<partition name>
-z
--zdumpname outputName (optional)
-n
--newonly (optional)
-o
--slot slotnum (optional)
-U
--unqualified-dev (FOR INTERNAL USE ONLY)
-L|--log
Extract the log from a compressed dump.
-S|--smart-activate
Activate the configured dump partition or find
the
first appropriate partition and use it
(same
order as -f).
-a|--activate
Activate the configured dump partition.
-d|--deactivate
Deactivate the active dump partition.